Series 65 Optical Smoke Detector 55000-317APO

Description

55000-317APO

The Series 65 Optical Smoke Detector uses light sensing technology to “see” smoke entering the chamber. The external detector moulding is identical to that of the ionisation detector, and has an indicator LED which is clear in quiescent state and produces a red light in alarm.

  • Responds well to slow-burning, smouldering fires
  • Well-suited to bedrooms and escape routes
  • Unaffected by wind or atmospheric pressure
  • Flashing LED and magnet operated test switch options

Additional Information

General
Warranty  :  10 year
Applications
B&Bs/guest houses

Bedrooms

Cafes

Restaurants

Retail

Small to medium buildings

Care homes

HMOs

Hospitals

Hotels

Industrial premises

Large vessels

Listed buildings

Medium to large buildings

Offices

University campuses

Warehouses

Fire Type  :  Slow burning, smouldering fires
Mechanical
Colour  :  White
Finish  :  Gloss
Sensor configuration  :  Horizontal optical bench housing infra-red emitter and sensor, arranged radially to detect forward scattered light.
Weight  :  0.22lbs
Weight  :  99g
Materials housing  :  Polycarbonate
Materials terminals  :  Nickel plated stainless steel
Product length  :  42mm
Product diameter  :  100mm
Detection principle  :  Photo-electric light scattering.
Product length  :  1.65in
Product diameter  :  3.94in
Conformance
Standards  :  EN 54-7
Approvals
BOSEC

CPR

FG

LPCB

VdS

Performance
Chamber type  :  Chevron
Electrical
Power-up surge current  :  0.115mA
Maximum power-up time  :  30 seconds
Status indicator – Alarm  :  Red
Status indicator – Fault  :  Off
Quiescent current  :  50μA
Quiescent current tested at  :  24V dc
Supply voltage (max)  :  33V dc
Supply voltage (min)  :  9V dc
Supply voltage (Vmin-Vmax)  :  9 to 33V dc
Terminal functions L2  :  -L2 Line in & out negative
Terminal functions L1 in  :  +L1 in
Terminal functions L1 out  :  +L1 out
Terminal functions -R  :  -R Remote indicator negative connection
Polarity  :  L1 & L2 are polarity insensitive
Battery powered  :  No
Sampling frequency  :  Once every 3 seconds
Holding voltage (min)  :  6V
Minimum voltage to light alarm LED :  12V
Alarm reset time  :  1s
Alarm load  :  420Ω in series with 2V drop
Environmental
Humidity (max)  :  95% RH
Humidity (min)  :  0% RH
Humidity Note  :  no condensation or icing
Humidity  :  0% to 95% (no condensation or icing)
Operating temperature  :  -20 to 60°C
Operating temperature (max)  :  60°C
Operating temperature (min)  :  -20°C
IP rating Value  :  IP23D
Storage temperature (max)  :  80°C
Storage temperature (min)  :  -30°C
Storage temperature  :  -30 to 80°C
Effect of wind speed  :  None
Operating temperature  :  -4 to 140°F
Operating temperature (max)  :  140°F
Operating temperature (min)  :  -4°F