Soteria Optical Smoke Detector SA5100-600APO

Description

SA5100-600APO

The Soteria Optical Smoke Detector uses advanced optical sensing technology, PureLight, to provide advanced false alarm management and increased detector reliability.

  • “Serpentine” pathway designed to provide a barrier against dust and insect ingress
  • Utilises digital Core Protocol communications providing a range of advanced fire detection features
  • A sophisticated dynamic algorithm, providing transient rejection and compensation for drift while maintaining accurate sensitivity
  • FasTest for quicker testing of detectors
  • Five response modes for adaptability to changing environments
  • Integrated switchable isolator

Additional Information

General
Warranty  :  10 year
Applications
Bedrooms

Cafes

Escape routes

Hotels

Restaurants

Retail

B&Bs/guest houses

Offices

University campuses

Fire Type  :  Slow burning, smouldering fires
Mechanical
Colour  :  White
Finish  :  Gloss
Sensor configuration  :  Chamber with surface-mount infrared emmiter and prism. Solid state integrated photo-diode and amplifier.
Weight  :  95g
Materials housing  :  Polycarbonate
Materials terminals  :  Tin plated stainless steel
Product diameter  :  100mm
Detection principle  :  Photo-electric light scattering.
Product diameter  :  3.94in
Conformance
Standards  :  EN 54-7
              EN 54-17
Approvals
SBSC

BOSEC

FG

LPCB

VdS

CPR

Performance
Analogue value nominal  :  23
Analogue value (- tolerance)  :  0
Analogue value (+ tolerance)  :  4
Analogue value  :  23 +4/-0
Alarm level analogue value  :  55
Chamber type  :  PureLight
Electrical
Protocol voltage  :  5 to 13V peak to peak
Protocol voltage (max)  :  13V
Protocol voltage (min)  :   5V
Power-up surge current  :  0.56mA
Status indicator – Alarm  :  Red
Status indicator – Fault  :  Flashing yellow
Quiescent current  :  350μA
Quiescent current tested at  :  24V dc
Terminal functions L2  :  +L2 Loop in & out positive
Terminal functions L1 in  :  -L1 in Loop (isolated) negative
Terminal functions L2 out  :  -L1 out Loop (isolated) negative
Terminal functions +R  :  +R Remote indicator positive connection
Terminal functions -R  :  -R Remote indicator negative connection
Polarity  :  L1 & L2 are polarity sensitive
Status indicator – Isolate  :  Yellow
Status indicator – Poll  :  Green
Sampling frequency  :  Once per second
Environmental
Humidity (max)  :  95% RH
Humidity (min)  :  0% RH
Humidity Note  :  no condensation or icing
Humidity  :  0% to 95% (no condensation or icing)
Operating temperature  :  -40 to 70°C
Operating temperature (max)  :  70°C
Operating temperature (min)  :  -40°C
IP rating Value  :  IP44
Effect of wind speed  :  None
Wind speed test  :  Tested up to 10m/s
Operating temperature  :  -40 to 158°F
Operating temperature (max)  :  158°F
Operating temperature (min)  :  -40°F